Three Phase Power Distribution Panels
Each PDU contains high quality UL Listed/Recognized Components to provide long life, reliable and safe operation.
Features of AC General Single Phase Distribution:
- 120/208 VAC 20A, 30A, or 60A service rating
- 60 Hz and 400 Hz Line Frequency
- Choice of Front or Rear Panel Power Entry
- AC EMI Line Filter at Power Input Stage removes incoming power line noise
- MOV Line Surge Protection
- Hydraulic/Magnetic Circuit Breakers provide highly precise, reliable overload protection
- Standard 19″ Equipment Rack Mounting
- Rugged Construction, Attractive Design
- Optional Remote Power Control
- Optional Phase Monitor-over/under voltage and phase rotation protection
- All PDUs contains high quality UL Listed/Recognized Components to provide safe, long life, reliable operation
60 Hz PDUs
400 Hz PDUs
Documents
Table of Standard Three Phase 20A PDUs 60Hz
| Input | Power Input | Switched Outputs | Unswitched | Remote Control | Voltage Monitoring | Part Number | |||
|---|---|---|---|---|---|---|---|---|---|
| Current | Voltage | Line Freq | Single Phase | Three Phase | Utility | ||||
| 20 | 120 | 60 | Front Panel | 8 | 1 (20A) | 0 | None | None | 030-060-20 |
| Front Panel | 6 | 1 (20A) | 2 | R | None | 030-060-20R | |||
| Front Panel | 6 | 1 (20A) | 2 | R | Under Voltage + Phase Rot | 030-060-20PR | |||
| Front Panel | 6 | 1 (20A) | 2 | R1 | None | 030-060-20R1 | |||
| Front Panel | 6 | 1 (20A) | 2 | R1 | Under Voltage + Phase Rot | 030-060-20PR1 | |||
| Power Cord- Rear | 8 | 1 (20A) | 0 | None | None | 300-060-20 | |||
| Power Cord- Rear | 6 | 1 (20A) | 2 | R | None | 300-060-20R | |||
| Power Cord- Rear | 6 | 1 (20A) | 2 | R | Under Voltage + Phase Rot | 300-060-20PR | |||
| Power Cord- Rear | 6 | 1 (20A) | 2 | R1 | None | 300-060-20R1 | |||
| Power Cord- Rear | 6 | 1 (20A) | 2 | R1 | Under Voltage + Phase Rot | 300-060-20PR1 | |||
| Click here for more info on 60Hz 20A Three Phase PDUs | |||||||||
Table of Standard Three Phase 30A PDUs 60Hz
| Input | Power Input | Switched Outputs | Unswitched | Remote Control | Voltage Monitoring | Part Number | |||
|---|---|---|---|---|---|---|---|---|---|
| Current | Voltage | Line Freq | Single Phase | Three Phase | Utility | ||||
| 30 | 120 | 60 | Front Panel | 8 | 1 (30A) | 0 | None | None | 030-060-30 |
| Front Panel | 6 | 1 (30A) | 2 | R | None | 030-060-30R | |||
| Front Panel | 6 | 1 (30A) | 2 | R | Under Voltage + Phase Rot | 030-060-30PR | |||
| Front Panel | 6 | 1 (30A) | 2 | R1 | None | 030-060-30R1 | |||
| Front Panel | 6 | 1 (30A) | 2 | R1 | Under Voltage + Phase Rot | 030-060-30PR1 | |||
| Power Cord- Rear | 8 | 1 (30A) | 0 | None | None | 300-060-30 | |||
| Power Cord- Rear | 6 | 1 (30A) | 2 | R | None | 300-060-30R | |||
| Power Cord- Rear | 6 | 1 (30A) | 2 | R | Under Voltage + Phase Rot | 300-060-30PR | |||
| Power Cord- Rear | 6 | 1 (30A) | 2 | R1 | None | 300-060-30R1 | |||
| Power Cord- Rear | 6 | 1 (30A) | 2 | R1 | Under Voltage + Phase Rot | 300-060-30PR1 | |||
| Click here for more info on 60Hz 30A Three Phase PDUs | |||||||||
Table of Standard Three Phase 60A PDUs 60Hz
| Input | Power Input | Switched Outputs | Unswitched | Remote Control | Voltage Monitoring | Part Number | |||
|---|---|---|---|---|---|---|---|---|---|
| Current[A] | Voltage[VAC] | Line Freq[Hz] | Single Phase | Three Phase | Utility | ||||
| 60 | 120/208 | 60 | Power Cord- Rear | 8 | 1 (30A) | 0 | None | None | 300-060-60 |
| Power Cord- Rear | 6 | 1 (30A) | 2 | R | None | 300-060-60R | |||
| Power Cord- Rear | 6 | 1 (30A) | 2 | R | Under Voltage + Phase Rot | 300-060-60PR | |||
| Power Cord- Rear | 6 | 1 (30A) | 2 | R1 | None | 300-060-60R1 | |||
| Power Cord- Rear | 6 | 1 (30A) | 2 | R1 | Under Voltage + Phase Rot | 300-060-60PR1 | |||
| Click here for more Info on 60Hz 60A Three Phase PDUs | |||||||||
Table of Standard Three Phase 20A PDUs 400Hz
| Input | Power Input | Switched Outputs | Unswitched | Remote Control | Voltage Monitoring | Part Number | |||
|---|---|---|---|---|---|---|---|---|---|
| Current | Voltage | Line Freq | Single Phase | Three Phase | Utility | ||||
| 20 | 120 | 400 | Front Panel | 8 | 1 (20A) | 0 | None | None | 030-400-20 |
| Front Panel | 6 | 1 (20A) | 2 | R | None | 030-400-20R | |||
| Front Panel | 6 | 1 (20A) | 2 | R | Under Voltage + Phase Rot | 030-400-20PR | |||
| Front Panel | 6 | 1 (20A) | 2 | R1 | None | 030-400-20R1 | |||
| Front Panel | 6 | 1 (20A) | 2 | R1 | Under Voltage + Phase Rot | 030-400-20PR1 | |||
| Power Cord- Rear | 8 | 1 (20A) | 0 | None | None | 300-400-20 | |||
| Power Cord- Rear | 6 | 1 (20A) | 2 | R | None | 300-400-20R | |||
| Power Cord- Rear | 6 | 1 (20A) | 2 | R | Under Voltage + Phase Rot | 300-400-20PR | |||
| Power Cord- Rear | 6 | 1 (20A) | 2 | R1 | None | 300-400-20R1 | |||
| Power Cord- Rear | 6 | 1 (20A) | 2 | R1 | Under Voltage + Phase Rot | 300-400-20PR1 | |||
| Click here for more info on 400Hz 20A Three Phase PDUs | |||||||||
Need More Information?
Interested in learning more about this product or how AC General can custom engineer a product specifically to fit your needs?
The easiest way to reach us is through our online contact form.